Products >> Continuous gas monitor - Sensonic 300 / Sensonic 400
Flue gas analyzer

Continuous gas monitor Sensonic 300/400

Continuous gas monitor Sensonic 300/400

Sensonic 300
Sensonic 400

Sensonic 300/400 is a high quality gas monitor. The device is produced using the latest technology. Due to the modular design of Sensonic 300/400 it is possible to meet the individual client's expectations by adjusting it to performing particular measurements, such as concentration of various gases, pressure, temperature and a number of boiler parameter measurements.

The monitor is in particular designed for flue (boiler) gas analysis, but it can be used for different purposes (such as producing biogas from garbage and animal excrements) as well.

Each Sensonic 300/400 gas monitor enables the user to measure concentrations of 3 or 4 gases. Additionally the device can present the measurement results on the liquid crystal displays and up to eight analog outputs. Independently of the built-in display equipment there is also the possibility of reading the measurement results and changing the settings with the help of the computer program provided.

Pictures...
Folder () Sensonic 300
Folder () Sensonic 400


Standard and optional configuration

Measurement of gas concentrations

  • Gas concentrations measured with NDIR sensors: CO, CO2, CH4, N2O
  • Gas concentrations measured with electrochemical sensors: O2, CO, NO, NO2, SO2, H2S. Please ask for quote for other gases.

Measurement of other parameters

  • Atmospheric pressure
  • Differential pressure
  • Temperature using thermocouples
  • Temperature using thermistors Pt-500

Processing and presentation of measuring data

  • Gas concentrations shown as ppm or mg/m3
  • All results shown as instantaneous values on display
  • Averaging of all measured values. Averaging time: 2 - 60 seconds for IR sensors and 2 - 30 seconds for EC sensors
  • Optional: Datalogger with 256 MB MMC (Memory card)
  • Powerful PC program for analyser settings and data communication
  • Optional calculation of combustion parameters: Lambda, qA, Eta
  • Optional calculation of NOx from NO or NO and NO2

Software capabilities

  • Stationary operation: Zeroing and measurement times user programmable
  • Permanent automatic check of the instrument
  • Compensation of cross sensitivity and temperature drift of gas sensors

Hardware capabilities

  • ABS housing for wall-mounting with internal ventilation
  • Microprocessor controlled
  • Correction of IR sensors with zero and one calibration gas possible
  • IR sensors (CO2 and CH4) with short reaction time (T90 < 15 seconds)
  • Integrated Peltier sample conditioner with cndensate pump and filter
  • Solenoid valve for automatic ventilation during zeroing
  • Membrane pump for sample extraction
  • 4 current (0/4 - 20 mA) and 4 voltage (0 - 10 V) analog outputs. Freely allocated to the measurment channels
  • Optional integrated clock/calendar
  • Up to 5 LCD displays. Freely allocated to the measurement channels
  • RS232C or RS485 connection for data transfer
  • Optional: Converter for connection to USB or Ethernet
  • PC programme for quick and simple configuration of hte instrument and data transfer

Possible uses

  • Biogas plants
  • Landfills
  • Greenhouses
  • Stationary control of combustion systems
  • Incinerators
  • Safety such as CO2 (0...2000 ppm) or CH4 (0...5 %)

Technical data

Size

W x H x D: 420 x 360 x 140 mm

Weight

5 kg

Power supply 24 VAC, 120 W
Gas pump Membrane pump
Gas filter In line filter 20 µm
Display LCD for each gas component
Data memory MMC Card 256 MB
Analog outputs Current 0/4 - 20 mA, Voltage 0 - 10 V, linear
Interface RS232C
Operating temperature 10°C ÷ 50°C
Storage temperature -20 °C ÷ +55 °C
Humidity 5 - 90 %, non-condensing

Description for IR sensors
Parameter Description
Measuring method NDIR absorption, single channel with light modulation
Averaging time 2 ÷ 60 s freely prgrammable
Calibration 10 point calibration stored in an EEPROM. Correction of the calibration curve with zero and single calibration gas
Recalibration not necessary

Description for electrochemical sensors
Parameter Description
Measuring method electrochemical
Averaging time 2 ÷ 30 s freely prgrammable
Calibration 2 point calibration
Recalibration at least every 12 months

Measurement
Parameter Measuring method Range Resolution Detection
Limit
Accuracy Time (T90)
Gases measured with IR sensors
CO - carbon monoxide, volumetric concentration

CO2 - carbon dioxides volumetric concentration,

CH4 - Methane, volumetric concentration

IR sensor 0...100 % 0.10 % 0.10 % +/-3 % of value,
or 0.5 % abs.
45 s
0....50 % 0.10 % 0.10 % +/-3 % of value,
or 0.3 % abs.
0...25 % 0.01 % (100 ppm) 0.01 % (100 ppm) +/-3 % of value,
or 0.15 % abs.
0...10 % 0.01 % (100 ppm) 0.01 % (100 ppm) +/-3 % of value,
or 0.05 % abs.
0...5 % 0.01 % (100ppm) 0.01 % (100ppm) +/-3 % of value,
or 0.03 % abs.
0...2.5 % 0.001 % (10 ppm) 0.001 % (10 ppm) +/-3 % of value,
or 0.015 % abs.
N2O - nitrous oxide, volumetric concentration 0...500 ppm 1 ppm 1 ppm +/-3 % of value,
or 5 ppm abs.
Gases measured with optional electrochemical sensors
CO - carbon monoxide, volumetric concentration electrochemical gas sensor 0...20000 ppm 1 ppm 1 ppm +/-5 % of value,
or 5 ppm abs.
45 s
NO / NOx - volumetric concentration of nitrogen oxides. 0...5000 ppm 1 ppm 1 ppm
NO2 - volumetric concentration of nitrogen dioxide 0...1000 ppm 1 ppm 1 ppm
SO2 - volumetric concentration of sulfur dioxide 0...5000 ppm 1 ppm 1 ppm
H2S - volumetric concentration of hydrogen sulfide 0...1000 ppm 1 ppm 1 ppm
H2 - volumetric concentration of hydrogen 0...2000 ppm 1 ppm 1 ppm
Gases measured with partial pressure sensors
O2 - oxygen, volumetric concentration Partial pressure 0...25 % 0.01 % 0.01 % +/-5 % of value,
or 0.2 % abs.
45 s